SmartPAC 2 with WPC Integration 1126800
SmartPAC 2 Fault Messages Chapter 7 page 397
Inter-processor failures
31* through 39*
Problem: These errors indicate failures that may occur within the main processor or
in the case of status code #38 and #39, in the second processor. The errors
are as follows:
F31 No reply received from second processor to check start request
F33 Incorrect reply received from second processor to mode change message
F34 No reply received from second processor to mode change message
F35 Incorrect reply received from second processor to power-up message
F36 No reply received from second processor to reset error message
F37 No reply received from second processor to compare input buffers
message
H38 The second processor did not receive the power up information correctly
H39 The second processor did not receive the mode information correctly
Remedy: Try to reset. If errors persist, contact Wintriss Tech Support for
assistance.
Input buffer test failures
41* through 44*
Problem: These errors indicate failures that may occur when WPC performs input
buffer tests within the main processor. The errors are as follows:
F41 Input buffer 1 check incorrect
F42 Input buffer 2 check incorrect
F43 Input buffer 3 check incorrect
F44 Input buffer 4 check incorrect
Remedy: Try to reset. If errors persist, contact Wintriss Tech Support for
assistance.