1126800 SmartPAC 2 with WPC Integration
Page 398 Chapter 7 SmartPAC 2 Fault Messages
Air pressure limits exceeded
45
Problem: These errors indicate that the main system air pressure is below the sensor
limit set in SmartPAC's Programming mode. This error can also be
generated by the second processor.
Remedy: Check the level of your press's system air pressure. If necessary, refer to
Chapter 4 to reset the limit. If you need more assistance, contact Wintriss
Tech Support.
46
Problem: These errors indicate that the counterbalance air pressure is outside the
sensor limits set in SmartPAC's Programming mode. This error can also
be generated by the second processor.
Remedy: Check the level of your press's counterbalance air pressure. If necessary,
refer to Chapter 4 to reset the limits.
NOTICE
TO RAMPAC USERS
This error should not appear if you use RamPAC to monitor the counterbalance pressure.
If this error does appear, make sure that RamPAC is wired correctly to its counterbalance
pressure sensor and that WPC is wired correctly to its pressure switch. See “Installing air
pressure & counterbalance switches instead of air pressure sensors” in Chapter 2. Contact
Wintriss Tech Support if you need further assistance.