1126800 SmartPAC 2 with WPC Integration
Page 56 Chapter 2 Installing SmartPAC 2 and WPC
Wiring a Remote Reset Switch (Optional)
The main WPC processor board has two terminals for wiring a remote reset switch. The
remote reset terminal can be wired to the equipment that you choose, or you can just use a
simple switch to activate the circuit. Connect a wire from terminal #70 on the main
processor board to a normally open switch. Connect another wire from the switch to ground.
WPC is reset with a momentary connection to ground.
Wiring Operator Mode Outputs (Optional)
SmartPAC with WPC provides outputs to customer-supplied solid-state relays to monitor
WPC’s operator mode. As an example, the following schematic illustrates how to monitor
when WPC is in Automatic Single Stroke.
Example showing wiring
for a relay to turn on when
Automatic Single Stroke
mode is selected.
Pin #
118
117
116
115
114
113
112
111
110
109
108
Pin Designation
+13.5 VDC (Power)
Ground
+5 VDC
(Unused)
ON in Continuous (2-Hand or Foot)
ON in Automatic Single Stroke
ON in Foot Single Stroke
ON in One-Hand Single Stroke
ON in Two-Hand Single Stroke
ON in Inch Mode (1-Hand or 2 Hand)
(Unused)
These operator mode outputs are
NOT control reliable. They can,
however, be used as a convenience to
interface automation.
WARNING
TB502
OPERATOR
MODE
OUTPUT
CONNECTOR
TB501
SERIAL COMM.
CONNECTOR
OPERATOR MODE
OUTPUTS CAN
SWITCH 8 MA OF
DC CURRENT TO
GROUND; MAX
VOLTAGE 24 VDC
J506
DISPLAY
BOARD
CONNECTOR
Figure 2 - 11. One Way to Wire WPC Operator Mode Outputs