EasyManuals Logo

Honeywell SmartPAC 2 User Manual

Honeywell SmartPAC 2
522 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #112 background imageLoading...
Page #112 background image
1126800 SmartPAC 2 with WPC Integration
Page 90 Chapter 2 Installing SmartPAC 2 and WPC
Connecting DiPro Sensor Interface to SmartPAC 2
You can connect your DiPro die protection sensors through the DSI 2 sensor interface. Refer
to the DSI 2 manual for more information. Terminate cable shields to ground studs close to
the point of entry into the enclosure.
Up to 8 sensors:
For sensors 1-8, follow the wiring instructions in Table 2 - 8 below.
9 to 16 sensors:
For sensors 1-8, follow the wiring instructions in Table 2 - 8, below.
For sensors 9-16, follow the wiring instructions in Table 2 - 9, below.
NOTICE
If you have an 8-sensor DiProPAC board, connect sensors 1 – 8 to TB501.
NOTICE
If there are extra wires in the cable, cut off the extras close to the end of the cable jacket.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell SmartPAC 2 and is the answer not in the manual?

Honeywell SmartPAC 2 Specifications

General IconGeneral
BrandHoneywell
ModelSmartPAC 2
CategoryControl Unit
LanguageEnglish

Related product manuals