DSVB driver
DSVA driver
Lockout driver
DSVB contact check
Lockout contact check
DSVA contact check
19 - unused
17 - Motor reverse
16 - Bar actuator
14 - Foot switch N/O
13 - Top Stop in Inch Disabled
+ 5 Logic B
+ 5 Logic A
+24VDC
G
R
O
U
P
5
GROUP 7GROUP 6
88 - Light curtain B 2
87 - Light curtain A 2
86 - User input 10
85 - User input 8
84 - User input 6
83 - User input 4
82 - User input 2
G
R
O
U
P
4
52 - Top stop 1 input
8 - System air pressure
7-Motorforward
6-Barselectorswitch
5 - External trip N/O actuator
48 - Estop 1 input
4 - Foot switch N/C
3-OnehandAN/O
2-PalmswitchN/CB
1-PalmswitchN/CA
G
R
O
U
P
1
22 - Fly wheel Sensor
20 - DSV lifeguard monitor
Prior act B switch
18 - User input 11
60 - Top stop 2 input
15 - External trip N/C actuator
57 - Estop 2 input
12 - Palm switch N/O B
11 - Palm switch N/O A
21 - User input 1
G
R
O
U
P
2
78 - Light curtain B 1
77 - Light curtain A 1
75 - unused
74 - User input 9
73 - User input 7
72 - User input 5
71 - User input 3
70 - Remote reset
26 - Unused
24 - Overrun limit switch
G
R
O
U
P
3
internal
internal
Figure B. WPC LED Map
44 Ground 88 Light curtain B 2 input –
43 Analog 2 input 87 Light curtain A 2 input
42 +13.5 VDC out 86 User input 10 – (paired with User input 11*)
41 +24 VDC out 85 User input 8 – (paired with User input 9*)
40 +24 VDC out 84 User input 6 –
39 +24 VDC out 83 User input 4 – (counterbalance press. if applic.)
38 +24VDC out 82 User input 2 +
37 +24 VDC out 81 Top stop string in (connects internally to 49)
36 Aux. 2 out 80 Top stop string center loop connection
35 Light curtain 2 enable 79 Top stop string drive output
34 Ground 78 Light curtain B 1 input –
33 Analog 1 input 77 Light curtain A 1 input
32 +13.5 VDC out 76 + 24 VDC out
31 Ground 75 Unused
30 Ground 74 User input 9 – (paired with User input 8*)
29 Aux. 3 out 73 User input 7 –
28 Aux. 1 out 72 User input 5 –
27 Light curtain 1 enable 71 User input 3 +
26 Unused 70 Remote reset input
25 Ground 69 Estop string in (connects internally to 45)
24 Overrun limit switch input – 68 Estop string center loop connection
23 +13.5 VDC out 67 Estop string drive output
22 Flywheel Sensor 66 Mute lamp output
21 User input 1 + 65 Palm time lamp output
20 DSV Lifeguard input + 64 Prior act lamp output
19 Unused 63 Prior act B input +
18 User input 11 – (paired with User input 10*) 62 Prior act B out
17 Motor reverse input + 61 Prior act A in (connects internally to 62)
16 Bar actuator input + 60 Top stop B 2 input + pulse
15 Automatic Single Stroke (Ext. Trip) actuator N/C + 59 Top stop B 2 out
14 Foot switch N/O input + 58 Top stop A 2 in (connects internally to 59)
13 Top Stop in Inch Disable + 57 Estop B 2 input + pulse
12 Palm switch B N/O input + 56 Estop B 2 out
11 Palm switch A N/O input + 55 Estop A 2 in (connects internally to 56)
10 Ground 54 Ground
9 + 24 VDC out 53 + 24 VDC out
8 Clutch air pressure switch input – 52 Top stop B 1 input + pulse
7 Motor forward input + 51 Top stop B 1 out
6 Bar selector switch input + 50 Top stop A 1 in (connects internally to 51)
5 Automatic Single Stroke (Ext. Trip) actuator N/O + 49 Top stop A out
4 Foot switch N/C input + 48 Estop B 1 input + pulse
3 One hand A input + 47 Estop B1 out
2 Palm switch B N/C input + 46 Estop A 1 in (connects internally to 47)
1 Palm switch A N/C input + 45 Estop out A
* See “Wiring WPC User Inputs,” page 52, and “User Interlocks,” page 225.