ADB
120 VAC
THIS OUTPUT WILL TURN ON WHEN THE DIPRO
SENSORS ARE DISABLED. IT IS AN OPEN COLLECTOR
TYPE OUTPUT AND CAN SINK 8 MA. TO GROUND.
302 (Relay Pwr)
293 (Sen 10)
294 (Sen 11)
295 (Sen 12)
296 (Sen 13)
297 (Sen 14)
298 (Sen 15)
299 (Sen 16)
282 (Sen 1)
283 (Sen 2)
284 (Sen 3)
285 (Sen 4)
286 (Sen 5)
287 (Sen 6)
288 (Sen 7)
289 (Sen 8)
290 (S Pwr)
292 (Sen 9)
300 (S Pwr)
304 (Aux 3)
303 (Aux 4)
305 (Aux 2)
306 (Aux 1)
DiProPAC 16
291 (Grd)
301 (Grd)
TB551
TB552
TB550
1
1
1
12 VDC SOLID-STATE
+ INPUT
- INPUT
OUTPUT
OUTPUT
RELAY
SENSORS 1 - 8
SENSORS 9 - 16
CUSTOMER SUPPLIED
REVISIONS
REV DESCRIPTION DATE APP’D
NONE
C
PROPRIETARY RIGHTS. This document discloses subject matter in which
thereof confers or transfers any right to reproduce or disclose the document,
any part thereof, any information contained therein or any physical article or
device, or to practice any method or process, except by written permission or
HONEYWELL has proprietary rights. Neither receipt nor possession
written agreement with HONEYWELL.
BRN
RED
ORG
YEL
GRN
BLUE
VLT
GRY
BLK
BLK
GRY
VLT
BLUE
GRN
YEL
ORG
RED
BRN
BRN
RED
ORG
YEL
GRN
BLUE
VLT
GRY
BLK
BRN
RED
ORG
YEL
GRN
BLUE
VLT
GRY
BLK
DiProPAC to DSI 2 Wiring Diagram
L1
L2
GND
1 - Sensor Power˜
3 - Sensor Input
SENSOR STATUS
2 - Ground
Sensor 1
Sensor 2
Sensor 3
Sensor 4
Sensor 5
Sensor 6
Sensor 7
Sensor 8
Sensor 1
Sensor 2
Sensor 3
Sensor 4
Sensor 5
Sensor 6
Sensor 7
Sensor 8
4 - N.C.
+24 VDC
+24 VDC
L1/+24V
OUTPUT
+5 VDC
INPUT
POWER
DSI 2
Grd
Grd
Grd
Grd
TB2
TB4
TB3
GND
10
L2
11
12
10
11
1
2
3
4
5
6
7
8
9
123
123456
7
8
1
2
3
4
5
6
7
8
9
1
2
3
4
1 - Sensor Power˜
3 - Sensor Input
SENSOR STATUS
2 - Ground
Sensor 1
Sensor 2
Sensor 3
Sensor 4
Sensor 5
Sensor 6
Sensor 7
Sensor 8
Sensor 1
Sensor 2
Sensor 3
Sensor 4
Sensor 5
Sensor 6
Sensor 7
Sensor 8
4 - N.C.
+24 VDC
+24 VDC
L1/+24V
OUTPUT
+5 VDC
INPUT
POWER
DSI 2
Grd
Grd
Grd
Grd
TB2
TB4
TB3
GND
10
L2
11
12
10
11
1
2
3
4
5
6
7
8
9
123
123456
7
8
1
2
3
4
5
6
7
8
9
1
2
3
4
OUT
GND
PNP PROX. SENSOR
+VDC
TYPICAL FOR MECHANICAL SENSORS.
USE THIS FOR MECHANICAL SWITCHES
AND SWITCHED PROBES.
USE THIS FOR UNSWITCHED PROBES.
THESE PROBES ARE GROUNDED BY THE
PART OR THE PRESS FRAME.
+24 VDC
N.C.
SENSOR IN
GND
+ Signal
- Signal
2 WIRE DC PROX. SENSOR
1
2
3
4
+24 VDC
N.C.
SENSOR IN
GND
1
2
3
4
+24 VDC
N.C.
SENSOR IN
GND
1
2
3
4
OUT
GND
+VDC
+24 VDC
N.C.
SENSOR IN
GND
1
2
3
4
NPN PROX. SENSOR
+24 VDC
N.C.
SENSOR IN
GND
1
2
3
4
SEE NOTE 1
SEE NOTE 1
SEE NOTE 1
SEE NOTE 1
THE WHITE, TAN AND PINK WIRES ARE NOT USED SEE NOTE 2.
NOTE 1: CONNECT THE SHIELD TO THE
NOTE 2: CUT THESE WIRES OFF CLOSE
ENCLOSURE CLOSE TO THE CONDUIT
ENTRY POINT.
TO THE END OF THE CABLE JACKET.
1.2 K
DO NOT CONNECT THE 24 VDC OUTPUTS
FROM THE UNITS TOGETHER.
WARNING: WHEN USING TWO DSI 2 UNITS,
1.2K IS A TYPICAL VALUE
(SEE INSTRUCTIONS FOR DETAILS)
FIGURE 10
CODE IDENT NO.
DRAWING NUMBER
APPROVALS
HONEYWELL
ACTON MA.
FILENAME
DRAWN
TITLE
SHEET
SCALE
DATE
CHK.
ENG.
MFG.
SIZE
REV
REL
OF
7/18/03