6 Remove the entrance guide. See “SHPF entrance guide removal” on page 446.
7 Remove the entrance sensor holder. See “Sensor (SHPF entrance) removal” on page 446.
8 Disconnect the cable (A).
9 Remove the two screws (B), and then set aside the cable holder.
10 Remove the clip (C), and then remove the bearing.
4021, 7421
Repair information
448