Diagnostic information 2-19
7500-432, -632, and -832
290.00
Scanner jam
Remove all
originals from
the scanner.
Switch (sheet through) static
jam
The system detected that the sensor (sheet
through) is on.
Go to “290.00 Switch (sheet through) static jam”
on page 2-83.
290.01
Scanner jam
Remove all
originals from
the scanner.
Sensor (sheet through) on
jam
After the first feed operation started, the feed drive
motor turned on (CW)) in Duplex mode, the sensor
(sheet through) did not turn on within the specified
time.
Go to “290.01 Sensor (sheet through) on jam” on
page 2-83.
290.02
Scanner jam
Remove all
originals from
the scanner.
Sensor (ADF pre-registration)
on jam ADF simplex side 1
After the Pre Feed operation started for the first
sheet, the feed drive motor turned on (CW)) in
Duplex or Simplex mode, the sensor (ADF pre-
registration) did not turn on within the specified time.
After the Pre Feed operation started for the second
sheet, the feed drive motor turned on (CW)) in
Duplex mode, the sensor (ADF pre-registration) did
not turn on within the specified time.
Go to “290.02 Sensor (ADF pre-registration) on
jam ADF simplex side 1” on page 2-86.
290.03
Scanner jam
Remove all
originals from
the scanner.
Sensor (ADF pre-registration)
off jam
After the sensor (sheet through) turned off in
simplex mode, the sensor (ADF pre-registration) did
not turn off within the specified time.
After the ADF registration motor turned on in duplex
mode, the sensor (ADF pre-registration) did not turn
off within the specified time.
Go to “290.03 Sensor (ADF pre-registration) off
jam” on page 2-88.
290.10
Scanner jam
Remove all
originals from
the scanner.
Sensor (ADF pre-registration)
static jam
The system detected that the sensor (ADF pre-
registration) is on.
Go to “290.10 Sensor (ADF pre-registration)
static jam” on page 2-90.
290.11
Scanner jam
Remove all
originals from
the scanner.
Sensor (ADF registration) on
jam ADF simplex side 1
After pre-registration started, the feed drive motor
turned on (CCW)), the sensor (ADF registration) did
not turn on within the specified time.
Go to “290.11 Sensor (ADF registration) on jam
ADF simplex side 1” on page 2-91.
290.12
Scanner jam
Remove all
originals from
the scanner.
Sensor (ADF registration) on
jam side 2
After the sensor (ADF pre-registration) turned on at
Invert, the sensor (ADF registration) did not turn on
within the specified time.
Go to “290.12 Sensor (ADF registration) on jam
side 2” on page 2-93
.
290.13
Scanner jam
Remove all
originals from
the scanner.
Sensor (ADF registration) off
jam
After the sensor (ADF pre-registration) turned off
during the Read operation, the sensor (ADF
registration) did not turn off within the specified time.
Go to “290.13 Sensor (ADF registration) off jam”
on page 2-95.
Error code or
message
Error contents Description/Action