Features
365
System functions and features as of R4.1
syd-0570/1.2 – R4.1 – 08.2016
WebAdmin:
After a first start, a call distribution element must be predefined with the call number
896 in the numbering plan. For this CDE, all switching positions of Switch group 1 Con-
ference bridge. However, more CDEs can also be configured with the routing destina-
tion conference bridge. It is important to define some call numbers for these call distri-
bution elements, through which internal conference participants can dial in to the con-
ference bridge.
So external users can also reach the conference bridge, a dialling in number must be
set up which points to this CDE.
The internal and external dialling in number are then entered in the Conferences
( =ex) view and displayed for each user in the Self Service Portal.
Note:
For a user to set up a conference room in the Self Service Portal, the administrator must grant
him the corresponding right.
Self Service Portal:
Each authorised user can set up one or more conference rooms via the Self Service
Portal. A 6-digit PIN is created automatically for each conference room. Clicking the
button copies the access data to an e-mail which can then be completed with the con-
ference date and time and sent to all conference participants.
Tip:
Conference rooms are basically managed via the users' Self Service Portal. However, all open
conference rooms can be seen via System assistant in WebAdmin with their status, usage
counter and last application, and can deleted by clicking the symbol.
Tab. 172 Conference bridge: System configuration
Reference to Other Features
"Hold (enquiry call)", page 356
"Variable and preconfigured conference", page 360
"Three-party conference from an enquiry call", page 362
Parameter Remarks
Managing conference rooms via Self Service Portal Permission set in the user configuration
Internal dial-in number displayed in the Self Service Portal Default: 896
External dial-in number displayed in the Self Service Por-
tal
Conference, intrusion and call waiting tone Setting valid throughout the system