ProSYS Installation and Programming Manual 11
Main Panel
The Main Panel is the foundation of the system's operation and has the following features:
8 basic hardwired zones
6 Utility Outputs:
1 x relay (programmable output) (3 Amps)
1 x 500mA transistor (Open Collector)
4 x 70mA transistors (Open Collector)
Box tamper input (normally open)
Bell tamper input (using a 2.2KΩ end-of-line resistor)
Two different 4-wire BUSes with "quick connectors" from the Main Panel, which is the
initial point for all system. If one BUS is shorted or there is any kind of problem that
interrupts the BUS data, the other one continues to operate normally
Power for the operation of an external sounder
Offers the required type of voltage for one or more electronic sirens, bells, or
loudspeakers, respectively
Supports more than 20 zone types
6 zone terminations, including: closed-circuit (NC), open-circuit (NO), end-of-line
(EOL) resistors, double end-of-line (DEOL) resistors, triple end-of-line (TEOL)
resistors (refer also to Chapter 2, Mounting and Wiring the Main Panel) and BUS
zone.
Event log (on board up to 256 events)
Zone Expansion
Support for additional 16 (ProSYS 16), 32 (ProSYS 40) or 120 (ProSYS 128) wired or
wireless zones
8-Zone or 16-Zone wired/wireless-868MHz expansion modules
6 zone terminations, including closed-circuit (NC), open-circuit (NO), end-of-line (EOL)
resistors, double end-of-line (DEOL) resistors and triple end-of line(TEOL) resistors
BUS zones support and BUS Zones expander
Supports more than 20 zone types
Forced setting zone capability
Wireless Devices
When using wireless zones, the ProSYS 8/16 Wireless expansion modules respond to
different wireless detectors, such as:
PIR/PET detectors
Smoke detectors
Door contacts/Door magnet/universal transmitter/door contact +universal
Up to 32 rolling code 4-buttons keyfobs
Double key panic keyfob
Flood detector
Shock detectors
CO detectors
Gas detectors
Glassbreak detectors
External PIR WatchOUT detectors
The Wireless expansion module includes the following features:

Table of Contents