68 ProSYS Installation and Programming Manual
Zones: Zone Type
Quick Keys Parameter Default Arming Level/Range
22
33
ZZZZ
+
/
1313
24 Hours
All
Usually assigned to protect non-movable glass, fixed skylights, and cabinets
(possibly) for shock detection systems.
A violation of such a zone causes an instant intrusion alarm, regardless of the
system's state.
22
33
ZZZZ
+
/
1414
Fire
All
For smoke or other types of fire detectors. This option can also be used for
manually triggered panic buttons or pull stations (if permitted), as follows:
If violated, it causes an immediate fire alarm, and the Fire
/ LED is lit
(steady).
A fault in the wiring to any fire zone causes a Fire Trouble signal (a rapid
flashing of the keypads' FIRE
/ LED).
22
33
ZZZZ
+
/
1515
Panic
All
Used for external panic buttons and wireless panic transmitters.
If violated, an immediate panic alarm is sounded (if the zone sound is not
defined as silent), regardless of the system's state. An alarm display will not
appear on the keypads.
If violated, an immediate panic alarm is sounded, regardless of the system's
state.
22
33
ZZZZ
+
/
1616
Special
All
For external auxiliary emergency alert buttons and wireless auxiliary
emergency transmitters.
If violated, an immediate auxiliary emergency alarm is sounded, regardless of
the system's state.
22
33
ZZZZ
+
/
1717
Pulse Keyswitch
Used to arm/disarm the system.
Connect an external momentary action keyswitch to any zone terminals given
this designation.
22
33
ZZZZ
+
/
1818
Exit Termination