50 ProSYS Installation and Programming Manual
Quick Keys Parameter Default Range
11
22
0606
Bell Squawk
YES YES/NO
ES: If a keyswitch or a rolling code remote control is used, a brief "chirp" is
produced from the system's external sounder(s) (at the conclusion of the Exit
Delay period), as follows:
♦ One chirp indicates the system is armed. (Also from keypad)
♦ Two chirps indicate the system is disarmed.
♦ Four chirps indicate the system is disarmed after an alarm.
NO: No "chirp" is produced.
11
22
0707
Bell 30/10
NO YES/NO
ES: Any internal sounders cease to sound for 10 seconds after each 30
seconds of operation.
NO: Any internal sounders operate without interruption.
11
22
0808
Alarm Phone Cut
NO YES/NO
ES: Activates the external sounders if the phone line is cut or the telephone
service is interrupted for the time defined in the Phone Line Cut Delay Time
parameter. (Refer to Phone Line Cut Delay Time, page 48.)
NO: No activation occurs.
11
22
0909
3 Minute Bypass
YES YES/NO
ES: Bypasses all zones automatically for 3 minutes when power is restored
to an "unpowered" system to allow for the stabilization of motion and/or smoke
detectors.
NO: No bypassing occurs.
11
22
1010
Double Verification of
Fire Alarms
NO YES/NO
ES: Implemented on detection of smoke or fire for verification. Power to the
smoke detector(s) in the affected zone is cut off and restored after the time
defined in Switched Auxiliary Break, page 47. If a subsequent detection
occurs in the same zone within 1 minute of the first detection, the system
emits a fire alarm.
NO: No fire alarm verification takes place.
NOTE:
This feature is supported through any Utility Output that is defined as Switch AUX.
11
22
1111
Audible Panic
NO YES/NO
ES: Any internal sirens operate when a "Police Alarm" is initiated at the
keypad or when a Panic Zone is activated.
NO: No internal siren operation occurs during a keypad "Police Alarm,"
making the alarm truly "silent" (Silent Panic).
NOTE:
The system also transmits a Panic report to the MS.