ProSYS Installation and Programming Manual 165
Accessories: Add Delete Module
Quick Keys Parameter Default Range
status indication will be indicated on the reader
14. Press
/ .
NOTE:
Recording tags can be performed only from Proximity Key Reader ID number 1.
77
11
99
22
Advanced Digital Voice Module
1. Press [2]. The following display appears:
2. With the cursor positioned at the TYPE field, use the / key
to toggle and choose the VOICE option.
3. Press
/ . The following display appears:
4. Type in a remote phone code and press / . The remote
code is used when calling the system from a remote phone. Refer to the
ProSYS User's Manual for additional details.
77
11
99
33
Advanced Communication Module (ACM)
1. Press [3]. The following display appears:
ACM MODULE:
TYPE=NONE
ACM MODULE:
TYPE=NONE
2. With the cursor positioned at the TYPE field, use the / key
to toggle and choose the ACM option.
3. Press
/ to store your choice.
NOTE:
If ACM module is found and NONE has been selected, Press / to
return to the prior display -OR- Press the / key to select [Y] YES
and press / to confirm the delete.
77
11
99
44
Siren
1. Press [4]. The following display appears:
OUT DOOR SIREN:
ID=1 TYPE=SIRN
2. Use the / or / keys to position the cursor
over the ID number to which you want to assign and configure the siren.
3. With the cursor positioned at the TYPE field, use the
/ key
to toggle and choose the SIRN option.