Zones Miscellaneous: BUS Zone – Lunar Grade 3/iWISE DT Grade 3
Quick Keys Parameter Default Range
22
00
33
ZZZZ
33
ACT
No
Defines the Anti-Cloakâ„¢ Technology (ACT) operation mode.
[1] No - Disables the ACT mode.
[2] Yes - Enables the ACT mode.
22
00
33
ZZZZ
44
Automatic Microwave
Bypass
No
Defines whether the MW channel will be bypassed or not while the detector
identifies trouble in the MW channel.
[1] No - While detecting a problem in the MW channel it is not bypassed. Alarm
condition cannot be established until the MW channel is fixed.
[2] Yes - Switches the detector to operate only in PIR mode in case of MW
trouble.
22
00
33
ZZZZ
55
Green Line
Yes
This option conforms to environmentally friendly standards by avoiding surplus
emission This feature defines the activation of the microwave channel while the
system is disarmed.
[1] No - Green Line feature is disabled. MW is constantly activated.
[2] Yes - Green Line feature is enabled.
22
00
33
ZZZZ
66
Anti-Mask
Enable
Defines the operation of Anti Masking detection.
[1] Disable [2] Enable and behaves according to the settings defined in quick
keys [2][0][3][zz][7].
22
00
33
ZZZZ
77
Arm/Disarm
No
Defines the operation of the anti masking detection while the detector is armed
or disarmed.
[1] No – While armed or disarmed, anti-mask behaves according to the setting
defined in quick keys [2][0][3][zz][6] above.
[2] Yes – While armed, anti-mask is disabled. When detector is disarmed Anti-
mask behaves according to the settings defined in quick keys [2][0][3][zz][6].
22
00
33
ZZZZ
88
Self Test
Remote
Used to test detection technologies. In the event of a failed test, a Self Test
Trouble is created.
[1] Remote (manual) - Performed by the system when a user manually selects
the Diagnostics option from the Maintenance menu via the ProSYS User
Functions menu.
[2] Local (automatic) - Once an hour, the detector automatically checks that the
detector’s channels are functioning properly.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Risco ProSYS series and is the answer not in the manual?

Risco ProSYS series Specifications

General IconGeneral
CommunicationIP, GSM, PSTN
Wireless ProtocolTwo-way wireless
Battery BackupYes
Remote ControlYes, via app
IntegrationRISCO Cloud

Related product manuals