ProSYS Installation and Programming Manual 149
Report Codes: Miscellaneous
Quick Keys Parameter Default
66
88
22
Exit Programming
00
Report Code for termination of the Installer Programming mode, either locally
(via the LCD keypad) or remotely (via the Upload/Download software).
66
88
33
Periodic MS Test
00
Report Code used for periodic MS Test transmissions. (Refer to Dialer:
Periodic Test, page 131, for additional details).
66
88
44
Periodic U/D Test
00
Report Code for the system's periodic Upload/Download (Auto Batch)
transmissions.
66
88
55
Call Back Request
00
Report Code for automatic callback to the MS’s Upload/Download software.
66
88
66
System Reset
00
Report Code for manual reset using the ProSYS DEFAULT (J2) jumper.
66
88
77
Abort Alarm
00
Report Code used when the system sends an ABORT message to the MS.
(Refer to Abort Alarm, page 52, for additional details.)
66
88
88
Self-Test OK
00
Report Code for confirmation of a successful Zone Self-Test. (Refer to page 80
for additional details).
66
88
99
Self-Test Failure
00
Report Code for verification of an unsuccessful Zone Self-Test. (Refer to
page 80 for additional details.)
66
88
00
More
More Options…
66
88
00
11
Cancel Report
00
Report Code for a user-initiated cancellation of an alarm in progress. (Refer to
the ProSYS User's Manual for additional details.)
66
88
00
22
Auto Arm Fail
Report code used when the system sends an Auto Arm Fail message to the
MS.
66
88
00
33
Listen In / Voice Alarm
Verification
You can call the MS and choose Listen in mode to listen to the events that
have occured.
The ProSYS enables the MS to perform Voice Alarm Verification in order to
verify a cause of event or to guide someone
in distress.
Note:
MS should support this feature and be configured to enable the operator the option
to perform the Listen-In and Talk functions.