ProSYS Installation and Programming Manual 141
Report Codes: Zones
Quick Keys Parameter Default
66
22
88
Low Battery
00
To report a low battery condition in a wireless transmitter.
66
22
99
Low Battery Restore
00
To report the correction of a low battery condition.
66
33
Report Codes: Accessory Tamper
The Accessory Tamper menu contains codes that enable reporting the violation (or restoral)
of the tamper switch on a system accessory (a keypad or expansion module).
Keypads have built-in tamper switches. Many expansion modules (Utility Outputs and Power
Supplies) also have an external tamper switch.
 To access the Accessory Tamper menu:
1 Access the Report Codes menu, as described on page 137.
2 From the Report Codes menu, press [3] to access the Accessory Tamper menu
options. The following display appears:
3 Access and configure the parameters in the Accessory Tamper menu, shown in the
table below, as follows:
O Use the [1 to 7] keys to select the event category (keypad, Utility Output module,
and so on).
O Press the event number (keypad tamper, utility output tamper restore, and so on).
O Enter the 2-digit keypad/utility output and the corresponding 2-digit Report Code
representing the event (tamper or tamper restoral). If the event is not to be
transmitted, use the 00 default.
NOTE:
If an accessory is not defined in the system, the default data will be (--) and not 00.
Report Codes: Accessory Tamper
Quick Keys Parameter Default
66
33
11
Keypad
00
[1] Keypad Tamper: Tamper Code for system keypad(s).
[2] Keypad Tamper Restore: Tamper Restore to Normal Report Code for
system keypad(s).
66
33
22
Utility Output Module
00
[1] Utility Output Tamper: Tamper Codes for utility output modules.
[2] Utility Output Tamper Restore: Tamper Restore to Normal Report Code for
utility output modules.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Risco ProSYS series and is the answer not in the manual?

Risco ProSYS series Specifications

General IconGeneral
CommunicationIP, GSM, PSTN
Wireless ProtocolTwo-way wireless
Battery BackupYes
Remote ControlYes, via app
IntegrationRISCO Cloud

Related product manuals