ProSYS Installation and Programming Manual 91
Zones Miscellaneous: BUS Zone – WatchOUT DT
Quick Keys Parameter Default Range
22
00
33
ZZZZ
11 LEDS
3 LEDS
Defines the LEDS operation mode.
[1] Off - Disables the LEDS operation.
[2] Red Only - Only the Red LED will operate. This option is highly
recommended to avoid the possibility that a burglar will “Learn” the detector
behavior.
[3] 3 LEDS - All 3 LEDs will operate.
22
00
33
ZZZZ
22 PIR Sensitivity
Normal
Defines the sensitivity of the detector (MW + PIR).
[1] Low [2] Medium [3] Normal [4] High
22
00
33
ZZZZ
33
MW Range
Trimmer
Defines the microwave channel range (maximum range – 23m).
[1] Minimum [2] 20% [3] 40% [4] 60% [5] 80% [6] Maximum [7] Trimmer (MW is
defined by the trimmer setting on the PCB)
22
00
33
ZZZZ
44
Alarm Logic
PIR and Microwave
Determine the detector’s logic of defining an alarm.
[1] PIR and Microwave – An alarm is activated when both PIR and MW
channels detect an alarm (AND Logic).
[2] PIR or Microwave - An alarm is activated when either PIR or MW channels
detect an alarm (OR Logic).
22
00
33
ZZZZ
55 Lens Type
Wide Angle
Defines the actual Lens of the detector.
[1] Wide Angle [2] Barrier / Long Range
22
00
33
ZZZZ
66 Anti-Mask
Enable
Defines the operation of Anti Masking detection.
[1] Disable [2] Enable
22
00
33
ZZZZ
77
Arm/Disarm
No
Defines the operation of the LEDs and the anti masking detections while the
detector is armed.
1) No – While armed, LEDS and anti-mask behave according to the settings
defined in quick keys [2][0][3][zz][1] and [2][0][3][zz][6] above.
2) Yes – While armed, both LEDS and anti-mask are disabled.
22
00
33
ZZZZ
88 Prox Anti mask
Enable
Defines the operation of proximity anti masking detection.
[1] Disable [2] Enable