86 ProSYS Installation and Programming Manual
Zones: Miscellaneous
Quick Keys Parameter Default Range
22
00
33
BUS Zone Parameters
The BUS Zone Parameters menu contains parameters that enable you to
program the special parameters of a BUS zone. The options are determined
according to the BUS detector type:
♦ Lunar Grade 3: A dual technology ceiling detector with a mounting height of
up to 8.6m (28ft) that incorporates Anti-Cloak
TM
Technology (ACT).
♦ WatchOUT DT: A dual technology outdoor detector with signal processing
based on two Passive Infrared (PIR) channels and two Microwave (MW)
channels.
♦ WatchOUT PIR: An outdoor detector with signal processing based on two
Passive Infrared (PIR) correlated channels
♦ WatchIN DT Grade 3: A dual technology Grade 3 industrial detector with
signal processing based on two Passive Infrared (PIR) channels and two
Microwave (MW) channels.
♦ iWISE DT Grade 2: A motion detector incorporating the Anti-CloakTM
Technology (ACT). It adheres to environmentally friendly guidelines and is
available in 15m and 25m models
♦ iWISE QUAD Grade 2: A motion detector incorporating Quad PIR
technology
♦ iWISE DT Grade 3: A motion detector incorporating both Anti-Mask and
Anti-Cloak
TM
Technologies (ACT). It adheres to environmentally friendly
guidelines and is available in 15m and 25m models.
♦ iWISE QUAD Grade 3: A motion detector incorporating Anti-Mask and
Quad PIR technologies.
Use the instructions below to set parameters for the relevant BUS zone
detector.
 To configure the BUS Zone detector parameters:
From the Miscellaneous menu, press [3] to access the BUS Zone parameters
menu options. The following display appears:
B-ZONE PRMS:
ZONE#=001 (M:ZZ)
B-ZONE PRMS:
ZONE#=001 (M:ZZ)
1 Select the zone that the BUS zone detector was assigned to and press
/ .
The BUS Zone parameters menu appears.
2 Use the below tables to configure the parameters for each BUS Zone detector type.
Zones Miscellaneous: BUS Zone – iWISE DT Grade 2
Quick Keys Parameter Default Range
22
00
33
ZZZZ
11
LEDS
On
Defines the LEDS operation mode.
[1] Off - Disables the LEDS operation.
[2] On - Enables the LEDS operation.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Risco ProSYS series and is the answer not in the manual?

Risco ProSYS series Specifications

General IconGeneral
CommunicationIP, GSM, PSTN
Wireless ProtocolTwo-way wireless
Battery BackupYes
Remote ControlYes, via app
IntegrationRISCO Cloud

Related product manuals