98 ProSYS Installation and Programming Manual
Utility Output: Partition
Quick Keys Parameter
33
22
1111
Exit/Entry Follow
Activates the Utility Output when the selected partition(s) initiates an Exit/Entry
Delay period.
33
22
1212
Fire Trouble Follow
Activates the Utility Output when a FIRE TROUBLE is detected in the selected
partition(s).
33
22
1313
Day (Zone) Trouble
Activates the Utility Output when a DAY ZONE TROUBLE is detected in the
selected partition(s).
33
22
1414
General Trouble Follow
Activates the Utility Output when a TROUBLE condition is detected in the
selected partition.
33
22
1515
Stay Follow
Activates the Utility Output when the selected partition(s) is armed in STAY
mode.
33
22
1616
Tamper Follow
Activates the Utility Output when a Tamper occurs in the selected partition(s)
and follows any type of tamper.
33
22
1717
Disarm Follow
Activates the Utility Output when the selected partition(s) is disarmed.
33
22
1818
Bell Follow
Activates the Utility Output when one of the defined partitions is in ALARM
mode and the bell is triggered. This enables the connection of different sirens
to different partitions.
33
22
1919
Bell Stay Off
This parameter causes the Utility Output to function as follows:
♦ In AWAY ARMING mode, the Utility Output will follow the bell activation in
the defined partitions.
♦ In STAY ARMING mode, the Utility Output will not be activated.
NOTE:
If an alarm occurs in a zone that shares more than one partition and one of the
partitions is in ARM mode (while the other is in STAY mode), the Utility Output
will be activated, as described above.
♦ In STAY mode, a 24-hour zone will not activate this Utility Output.
33
22
2020
Zone Bypass
Activates the Utility Output when the relevant partitions are in ARM or STAY
mode and any zone in the relevant partitions is bypassed.
33
22
2121
Automatic Arm Alarm
Automatically activates an alarm when an event occurs.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Risco ProSYS series and is the answer not in the manual?

Risco ProSYS series Specifications

General IconGeneral
CommunicationIP, GSM, PSTN
Wireless ProtocolTwo-way wireless
Battery BackupYes
Remote ControlYes, via app
IntegrationRISCO Cloud

Related product manuals