ProSYS Installation and Programming Manual 95
Utility Output: System
Quick Keys Parameter
33
11
0505
Ground Pulse
Activates when the ProSYS dialer dials out.
This option is rarely used and is intended for older phone systems that require
a "Ground Start" (a momentary connection between one side of the phone line
and "earth") to obtain a dial tone.
When the Utility Output is programmed (and properly wired) for this purpose, it
provides the 2-3 pulses needed to furnish a dial tone to the dialer.
If the Ground Pulse parameter is used, the Pattern of Operation options,
page 100, do not apply.
33
11
0606
Low Battery Follow
Activates when the ProSYS rechargeable standby battery has insufficient
reserve capacity and the voltage decreases to 11.5V.
33
11
0707
AC Loss Follow
Activates when the source of the Main Panel's AC power is interrupted. This
activation will follow the delay time defined in the system control times and the
AC Off Delay Time parameter (refer to page 48).
33
11
0808
Sensors Test
Relates to the ProSYS Zone Self-Test (Quick Keys [2][9][8]) described on
page 80.
This option is selected if the designated Utility Output is part of the circuit
providing switched power for the source of noise (or vibration) used in the
Sensors Test procedure.
33
11
0909
Voice Module
When a Follow-Me number is dialed due to an alarm, this Utility Output
activates the Voice module (RP200VC), which plays a pre-programmed
message repeatedly. The Utility Output deactivates after the Follow-Me period
is completed.
33
11
1010
Battery Test
A pulsed Utility Output will follow the Battery Test only once a day at 9:00 AM.
The pulse interval is 10 seconds. This parameter is usually used to perform an
overload test on the system by using an external device.
33
11
1111
Bell Burglary
Activates the Utility Output after any bell burglary alarm in any partition in the
system.
33
11
1212
Scheduler
The Utility Output will follow the predefined time programming that is defined in
the scheduler of the weekly programs for Utility Output activation. For
additional details, refer to the ProSYS User's Manual.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Risco ProSYS series and is the answer not in the manual?

Risco ProSYS series Specifications

General IconGeneral
CommunicationIP, GSM, PSTN
Wireless ProtocolTwo-way wireless
Battery BackupYes
Remote ControlYes, via app
IntegrationRISCO Cloud

Related product manuals