144 ProSYS Installation and Programming Manual
Report Codes: Main Trouble
Quick Keys Parameter Default
66
44
22
Trouble Restorals
00
Trouble restoral codes assigned to the ProSYS Main Panel:
[1] Low Battery: reports the restoring to normal of a weak (or missing) standby
battery.
[2] Bell: reports the restoring to normal of an internal sounder wired to the Main
Panel.
[3] Phone: reports the restoring to normal of the telephone service to ProSYS.
[4] AC: reports the restoring to normal of AC power supply to the ProSYS.
[5] AUX: reports the restoring to normal of Auxiliary Power (either continuous
or switched) supplied by the ProSYS.
[6] Clock Is Set: 2-digit code to report that the system's clock is now set.
[7] BUS Comm: report the restoring to normal of the system's 4-wire BUS.
[8] False Code: reports user viewing in the View Trouble menu. (Refer to the
ProSYS User's Manual for additional details.).
[9] Bell Tamper: reports the restore of a bell tamper.
[0] Box Tamper: reports the restore of a box tamper.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Risco ProSYS series and is the answer not in the manual?

Risco ProSYS series Specifications

General IconGeneral
CommunicationIP, GSM, PSTN
Wireless ProtocolTwo-way wireless
Battery BackupYes
Remote ControlYes, via app
IntegrationRISCO Cloud

Related product manuals