94 ProSYS Installation and Programming Manual
1 Press
/ to disable the selected utility output.
33
11
Utility Output: System
The System menu contains Utility Output parameters that follow the System Event.
 To access the System menu:
Access the Utility Output menu, as described on page 93.
1 From the Utility Output menu, press [1] to access the System menu options. The following
display appears:
2 Press
/ . The following display appears:
3 Access and configure the parameters in the System menu, as follows:
Utility Output: System
Quick Keys Parameter
33
11
0101
Bell Follow
Activates when a bell is triggered.
If a bell delay was defined, the Utility Output will be activated after the delay
period. (Refer to Bell Delay, page 47.)
33
11
0202
No Telephone Line
Activates in the following cases:
1. When a telephone line fault is detected. If a Phone Line Cut Delay time
period is defined, the Utility Output will be activated after the delay time. (Refer
to Phone Line Cut Delay Time, page 48.)
2. When the AGM module is connected to the ProSYS, the Line Fault output is
activated when there is a loss of phone line simulation connection between the
AGM Module and the ProSYS (meaning there is both AGM and PSTN loss).
Deactivates after the telephone line fault has been corrected.
33
11
0303
Communication Failure
Activates when communication with the MS cannot be established.
Deactivates after a successful call is established with the
MS.
33
11
0404
Trouble Follow
Activates when a system trouble condition is detected.