78 ProSYS Installation and Programming Manual
Zones: Maintenance
Quick Keys Parameter
22
99
55
Wireless Module Calibration
Measures the RF noise that the receiver is picking up. This is used for
j
amming
indication in order to eliminate false jamming alarms. The range is 00-99.
1. Press [5]. The following display appears:
2. Select the wireless zone expander for which you want to establish the
threshold level and press
/ . The following display appears,
showing the current threshold level:
3. To perform a new automatic calibration, use the / key to
select
[Y] YES.
After the calibration process is finished, the new receiving threshold is
displayed, as follows:
4. To confirm the new threshold, press / ,
-OR-
To change the threshold manually, enter the required level and
press
/ .
NOTES:
In order to ensure that a momentary high noise level (due to environmental
reasons) will not cause a jamming alarm, you can set the threshold level to be
higher than the calibrated level.
22
99
66
Wireless Zone Allocation
The following information relates to the assignment of zone attributes (for
example, Zone ID, Partition, Type, Sound, and so on) to any ProSYS wireless
detectors.
In order to receive data from wireless detectors, the ProSYS requires at least
one Wireless Zone Expander.
In order for the system to allocate a wireless detector, the system must first be
introduced to the detector, as follows:
Press [6]. The following display appears:
NOTE:
Wireless background information for the ProSYS is provided in the instructions
provided with the Wireless expansion module and the system's individual
transmitters.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Risco ProSYS series and is the answer not in the manual?

Risco ProSYS series Specifications

General IconGeneral
CommunicationIP, GSM, PSTN
Wireless ProtocolTwo-way wireless
Battery BackupYes
Remote ControlYes, via app
IntegrationRISCO Cloud

Related product manuals