174 ProSYS Installation and Programming Manual
6 Press
/ and then press / and / to confirm
your selection.
88
22
Miscellaneous: Siren
The Siren menu enables defining all parameters of an external siren that can be connected to
the ProSYS as a BUS accessory.
Up to 8 sirens can be added to the ProSYS and each can be assigned to any partition.
Connection to the BUS enables Remote Control and Diagnostic support for a siren.
Siren Parameters
Quick Keys Parameter Default
88
22
11
Strobe Control Follow Bell
Defines the Strobe operation mode
[1] Always Off - The strobe is deactivated.
[2] Follow Bell - The strobe is activated when the siren bell is triggered.
[3] Follow Alarm - The strobe is activated when an alarm occurs in the
selected siren’s partitions.
88
22
22
Strobe Blink
40
Defines the number of times that the strobe will blink in a minute .
[1] 20 [Times/Min]
[2] 30 [Times/Min]
[3] 40 [Times/Min]
[4] 50 [Times/Min]
[5] 60 [Times/Min]
88
22
33
Strobe Arm SQK
Default: 01 Range: 01-20
(seconds)
The time that the strobe will blink when the system is armed.
Note: If the siren’s squawk strobe is defined as NO (Refer to the Add
Delete Module, Siren section, page 165) this parameter will be
ignored.
88
22
44
Siren LED
Follow Arm
Defines the operation mode of the Status LED2.
[1] Always On - The status LED2 is always on
[2] Always Off - The status LED2 is deactivated
[3] Follow Arm - The status LED2 is activated when any of the siren selected
partition is armed (Away or Stay mode)
[4] Follow Alarm - The status LED 2 is activated after any alarm condition
88
22
55
Proximity Level Response
3 0-9 sec
Defines the time (seconds) for which a proximity violation must exist before
the siren will trigger an anti approach alarm. The option 0 indicates that the
proximity is deactivated.