90 ProSYS Installation and Programming Manual
Zones Miscellaneous: BUS Zone – Lunar Grade 3/iWISE DT Grade 3
Quick Keys Parameter Default Range
22
00
33
ZZZZ
55
Self Test
Remote
Used to test detection technologies. In the event of a failed test, a Self Test
Trouble is created.
[1] Remote (manual) - Performed by the system when a user manually selects
the Diagnostics option from the Maintenance menu via the ProSYS User
Functions menu.
[2] Local (automatic) - Once an hour, the detector automatically checks that the
detector’s channels are functioning properly.
Zones Miscellaneous: BUS Zone – WatchOUT PIR
Quick Keys Parameter Default Range
22
00
33
ZZZZ
11
LEDS
3 LEDS
Defines the LEDS operation mode.
[1] Off - Disables the LEDS operation.
[2] Red Only - Only the Red LED will operate. This option is highly
recommended to avoid the possibility that a burglar will “Learn” the detector
behavior.
[3] 3 LEDS - All 3 LEDs will operate.
22
00
33
ZZZZ
22
PIR Sensitivity
Normal
Defines the PIR sensitivity of the detector.
[1] Low [2] Medium [3] Normal [4] High
22
00
33
ZZZZ
33
Lens Type
Wide Angle
Defines the actual Lens of the detector.
[1] Wide Angle [2] Barrier / Long Range
22
00
33
ZZZZ
44
Auxiliary Relay Mode
Off
Defines the operation of the Auxiliary relay of the detector.
[1] Off - Auxiliary relay is disabled.
[2] 24 Hours - The auxiliary relay will always follow an alarm.
[3] Night Only - The auxiliary relay output will follow an alarm condition only
during night time. The time defined by the photocell on the PCB.
22
00
33
ZZZZ
55
Auxiliary Relay Time
2.2 seconds
Defines the time duration that the auxiliary relay is activated.
[1] 2.2 seconds [2] 2 minutes [3] 4 minutes [4] 8 minutes