92 ProSYS Installation and Programming Manual
Zones Miscellaneous: BUS Zone – WatchIN DT Grade 3
Quick Keys Parameter Default Range
22
00
33
ZZZZ
11
LEDS
3 LEDS
Defines the LEDS operation mode.
[1] Off - Disables the LEDS operation.
[2] Red Only - Only the Red LED will operate. This option is highly
recommended to avoid the possibility that a burglar will “Learn” the detector
behavior.
[3] 3 LEDS - All 3 LEDs will operate.
22
00
33
ZZZZ
22
Detection Sensitivity
Normal
Defines the sensitivity of the detector (MW + PIR).
[1] Low [2] Medium [3] Normal [4] ACT (Anti-Cloak™ Technology)
22
00
33
ZZZZ
33
MW Range
Trimmer
Defines the microwave channel range (maximum range – 27m).
[1] Minimum [2] 20% [3] 40% [4] 60% [5] 80% [6] Maximum [7] Trimmer (MW is
defined by the trimmer setting on the PCB)
22
00
33
ZZZZ
44
Alarm Logic
PIR and Microwave
Determine the detector’s logic of defining an alarm.
[1] PIR and Microwave – An alarm is activated when both PIR and MW
channels detect an alarm (AND Logic).
[2] PIR or Microwave - An alarm is activated when either PIR or MW channels
detect an alarm (OR Logic).
22
00
33
ZZZZ
55
Lens Type
Wide Angle
Defines the actual Lens of the detector.
[1] Wide Angle [2] Barrier/Long Range
22
00
33
ZZZZ
66
IR Anti-Mask
Enable
Defines the operation of IR Anti Masking detection.
[1] Disable [2] Enable
22
00
33
ZZZZ
77
Arm/Disarm
No
Defines the operation of the LEDs and the anti masking detections while the
detector is armed.
[1] No While armed, LEDS and anti-mask behave according to the settings
defined in quick keys [2][0][3][zz][1] and [2][0][3][zz][6] above.
[2] Yes – While armed, both LEDS and anti-mask are disabled.
22
00
33
ZZZZ
88
Green Line
Yes
This feature defines the activation of the microwave channel while the system
is disarmed.
[1] No - Green Line feature is disabled. MW is constantly activated.
[2] Yes - Green Line feature is enabled. This option conforms to
environmentally friendly standards by avoiding surplus emission.
22
00
33
ZZZZ
99
Sway
No
This option allows the recognition and immunity of swaying objects in a known
pattern.
[1] No - Sway is disabled.
[2] Yes - Sway is enabled.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?