ProSYS Installation and Programming Manual 119
3 Access and configure the parameters in the Controls menu, shown in the table below, as
follows:
O Access each parameter by pressing the menu number keys or by using the
/
or / keys.
O Press the
/ key to toggle between [Y] YES and [N] NO and press /
(repeat for each parameter, as required).
O Press the
key to return to the Dialer menu.
Dialer: Controls
Quick Keys Parameter Default
55
55
0101
MS Enable
YES
Y
ES: Enables communication with the MS to report alarms, trouble, and
supervisory events.
NO: No communication with the
MS is possible. Choose NO for installations
that are NOT monitored by a
MS.
55
55
0202
FM Enable
YES
Y
ES: Enables Follow-Me communication. (Refer to Follow-Me, page 125.)
If both the MS phones and the FM phones are defined, the system will first call
the MS phones and then the FM phones.
NO: Disables Follow-Me communication.
55
55
0303
U/D Enable
YES
Y
ES: Enables communication between the MS and the ProSYS Main Panel
using the Upload/Download software. This enables modifying an installation's
configuration, obtaining status information, and issuing Main Panel commands,
all from a remote location.
NO: Disables communication, as detailed above.
55
55
0404
Call Delay
YES
Y
ES: Event reports to the MS are delayed for 15 seconds after they are
detected.
NO: Event reports are sent immediately.
55
55
0505
Dial Tone
YES
Y
ES: The ProSYS waits a short (selectable) interval to detect a dial tone
before dialing the
MS. (Refer to Dial Tone Time, page 122.)
NO: The ProSYS dials without waiting.
55
55
0606
Call Save
NO
Y
ES: For reducing MS traffic congestion, the system holds all
non-urgent events (for example, opening/closing reports, test transmissions)
for up to 12 hours (programmable) and sends them as a batch at a less busy
time, for example, at night. (Refer to Dialer: Periodic Test, page 131.)
NO: All events are transmitted as they occur.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Risco ProSYS series and is the answer not in the manual?

Risco ProSYS series Specifications

General IconGeneral
CommunicationIP, GSM, PSTN
Wireless ProtocolTwo-way wireless
Battery BackupYes
Remote ControlYes, via app
IntegrationRISCO Cloud

Related product manuals