ProSYS Installation and Programming Manual 51
11
22
1212
Buzzer-->Bell
NO YES/NO
ES: If an alarm occurs when the system is armed in the STAY mode, each
keypad sounds for 15 seconds before the external sounders operate.
NO: An alarm in the STAY mode causes each keypad and any internal
sounders to operate simultaneously.
11
22
1313
Alarm ZE Cut
NO YES/NO
ES: Produces an alarm if the communication between the Main Panel and
any expander is lost. A report is transmitted to the MS.
NO: No alarm occurs. The system, however, produces a local trouble
indication.
11
22
1414
Fire Temporal Pattern
NO YES/NO
ES: During a fire alarm, the external sounders produce a pattern of three
short bursts, followed by a brief pause.
NO: During a fire alarm, the flow of sounds produced by the external sounder
is a pattern of 2 seconds ON, then 2 seconds OFF.
11
22
1515
Code Grand Master
NO YES/NO
ES: Only a user with the Grand Master Authority Level can change all User
Codes, along with the TIME and DATE.
NO: Users with the Master and Manager Authority Levels can change their
own User Codes, all codes with a lower Authority Level, and the TIME and
DATE.
11
22
1616
Audible Jamming
NO YES/NO
Relates to the Jamming Time parameter, described on page 48.
ES: Once the specified time is reached, the Main Panel activates any
internal sounders and sends a Report Code to the MS. (Refer to Jamming
Trouble, page 151.)
NO: Same as above, except the internal sounders do not operate.
11
22
1717
Technician Tamper
NO YES/NO
ES: It is necessary to enter the Installer Code to reset a Tamper Alarm
(indicated by a lit keypad Tamper /
LED). Therefore, Tamper Alarm (and
Tamper /
LED) resets require the intervention of the MS. However, the
system can still be armed although the Tamper /
LED is on.
NO: A Tamper Alarm (and the resulting Tamper /
LED) is reset by
correcting the problem, requiring no
MS help.
11
22
1818
Technician Reset
NO YES/NO
ES: It is necessary to enter the Installer Code to reset an alarmed partition
after it's been disarmed. This requires the intervention of the
MS.
NOTE:
Before the READY/ LED can light, all zones within the partition must be
secured.
NO: Once an alarmed partition is reset, the READY / LED lights when all
zones are secured.