52 ProSYS Installation and Programming Manual
11
22
1919
Abort Alarm
NO YES/NO
ES: If an alarm is sent in error, it is possible for the MS to receive an Abort
Alarm Code, sent subsequent to the initial Alarm Code. This happens if a valid
User Code is entered to reset the alarm within 90 seconds of initiation.
NO: No Abort Alarm Code can be sent once an alarm has been triggered.
Quick Keys Parameter Default Range
11
22
2020
Summer/Winter Clock
NO YES/NO
ES: The ProSYS automatically sets its Time of Day clock one hour ahead in
the spring (on the last Sunday in March) and one hour back in the Autumn (on
the last Sunday in October).
NO: No automatic time accommodation is made.
11
22
2121
Forced Keyswitch Arming
YES YES/NO
ES: Keyswitch or Proximity Key arming is performed on any partition. Any
violated (not READY) zone(s) in the partition will be bypassed automatically.
The partition is then "force armed," and all intact zones are capable of
producing an alarm.
NO: The partition cannot be armed using a keyswitch or Proximity Key until all
violated (not READY) zones are secured.
11
22
2222
Pager
NO YES/NO
Relates to the use of an alphanumeric pocket pager with the option to notify
the customer when an event occurs. The pager's phone number must be
programmed as a Follow-Me device in the ProSYS's User Functions.
ES: When a call is made, event information is displayed on the
alphanumeric pager.
The following examples and tips clarify the YES option.
1. Enter the phone number, as described in the ProSYS User's Manual, by
entering the letter [B] (which instructs the dialer to wait a fixed period of
time before continuing).
2. Add the partition number to which the Follow-Me relates.
3. The following messages are delivered automatically to the pager.
Displayed
eaning
1# The system (or partition) is armed.
2#
he system (or partition) is disarmed.
3#
he system (or partition) is in ALARM mode.
In the example below, the first column displays the characters that are added
after you enter the letter [B]:
Characters Added
After [B]
If Displayed Meaning
1 11# Partition 1 is armed.
2 21# Partition 2 is armed.
3 32# Partition 3 is disarmed.
8 83# Partition 8 is in ALARM mode.
NO: The ProSYS calls a pager during an alarm situation only in the partition
for which it is programmed as a Follow-Me device. There are no
enhancements to the standard message.