EasyManua.ls Logo

Risco ProSYS series - Dialing Method; Swinger Limit (Swinger Shutdown)

Risco ProSYS series
232 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ProSYS Installation and Programming Manual 123
Dialer: Parameters
Quick Keys Parameter Default Range
55
66
55
11
Wait 5 Seconds
Select [1] and press / .
55
66
55
22
Wait 60 Seconds
Select [2] and press / .
55
66
66
Dialing Method
DTMF DTMF (Touch
Tone ®), Pulse @ 20 BPS,
and Pulse @ 10 BPS
When selecting the dialing method, your choice must be compatible with the
type of phone service available at the protected premises.
Use the
/ or / keys to choose between the
options.
55
66
66
11
DTMF (Touch Tone ®)
Select [1] and press / to activate the DTMF dialing method.
55
66
66
22
Pulse @ 20 BPS (pulses per second)
Select [2] and press / to activate the Pulse @ 20 BPS dialing
method.
55
66
66
33
Pulse @ 10 BPS (pulses per second)
Select [3] and press / to activate the Pulse @ 10 BPS dialing
method.
55
66
77
Pulse Duty Cycle
61/39% 67/33% and 61/39%
For pulse dialing, choose the proper dialing duty cycle for the location, as
described below.
55
66
77
11
67/33%
Select [1] and press / for European telephone systems.
55
66
77
22
61/39%
Select [2] and press / for USA telephone systems.
55
66
88
Swinger Limit (Swinger
Shutdown)
00 00 to 15
A swinger is a repeated violation of the same zone, often resulting in a
nuisance alarm and usually due to a malfunction, an environmental problem, or
the incorrect installation of a detector or sensor.
This parameter specifies the number of violations of the same zone reported
during a single armed period, before the zone is automatically bypassed.
NOTE:
Enter 00 to disable the swinger shutdown.

Table of Contents