Remote Control Commands
R&S
®
SMW200A
1019User Manual 1175.6632.02 ─ 30
14.19.4.3 SOURce:BB:ARBitrary Subsystem
This section list the commands of the SOURce:BB:ARBitrary subsystem.
Suffixes in the keywords ENTity<ch> and SOURce<hw>
You can address multiple entities configurations by using the SCPI commands starting
with the keyword SOURce or the alias commands starting with the keyword ENTity.
Table 14-6: Value ranges of the suffixes ENTity<ch> and SOURce<hw> in advanced configuration
with multiple entities
SCPI Syntax
ENTity<ch> SOURce<hw>
SOURce<hw>:BB:...
- 1 to 8
ENTity<ch>:SOURce<hw>:BB:...
1 1 to 8
2 to 4 1 to 4
See also Chapter 14.3, "SCPI Command Aliases for Advanced Mode with Multiple
Entities", on page 842.
Required options
See Chapter 5.7.1, "Required Options", on page 296.
The commands are grouped in the following sections:
Programming Examples......................................................................................1019
General Commands............................................................................................1028
Test Signal Commands....................................................................................... 1029
Waveform Commands........................................................................................ 1033
Multi-Segment Commands..................................................................................1038
Multi-Segment Sequencing Commands..............................................................1043
Multi-Carrier Commands.....................................................................................1046
Notch Filter Commands...................................................................................... 1058
Trigger Commands............................................................................................. 1061
Marker Commands..............................................................................................1067
Clock Commands................................................................................................1070
Programming Examples
Example: Creating test signals
The following example lists commands necessary to configure the different test sig-
nals.
// ******************************************************************
// Reset instrument first
// ******************************************************************
*RST; *CLS
SOURce:BB:ARBitrary:PRESet
SOURce Subsystem