9. After you run the "Generate batch types" function, the configured data is made available.
10.If you have configure one or more enumerations as an equipment property, you can set
one of them as a group criterion for the recipe editor. Select the "Pcell" folder and select
the desired process cell group for the "Unit group".
Result
You have assembled several units with identical properties in a unit group. When creating the
recipe, you use the unit group as a criterion for the unit allocation.
See also
Specifying units using conditions (Page 525)
7.1.8 Configuring transfer of archive data from WinCC archives
Introduction
The batch data also includes the values of important process variables over time. SIMATIC
BATCH does not record these measured value sequences, but fetches the values from the
WinCC measured value archives. For each instance parameter to be recorded as a measured
value,
the "Archive measured variable" option must activated and
a WinCC archive tag must be assigned.
Engineering
7.1 Basic engineering for PCS 7
SIMATIC BATCH V8.2
172 Operating Manual, 02/2016, A5E35958174-AA

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC BATCH and is the answer not in the manual?

Siemens SIMATIC BATCH Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC BATCH
CategoryControl Systems
LanguageEnglish

Related product manuals