Unit class:
The unit class selected in the RUP in the "Allocations" tab is output.
Preferred unit:
The selected preferred unit for the unit class is output in the RUP in the "Allocations" tab.
Run time:
You can enter a time that you have determined for the run time of this function. The format is
day:hours:minutes:seconds.
Description of the function:
The text entered in basic engineering for the EOP or EPH or in the library sequence is
displayed.
14.1.10.7 "General" tab (ROP sequence properties)
Substitute representation for sequence
A ROP sequence is the substitute for a step sequence in the graphic representation of the
recipe unit procedure. In the underlying step sequence, only phases of the type EPH can be
addressed.
Name:
You can assign a name to an ROP.
Unit class:
The unit class selected in the "Allocation" tab is displayed.
Preferred unit:
The preferred unit selected in the "Allocation" tab is displayed as the unit class.
"Runtime" in seconds text box
This is where the longest time for a straight cycle of the recipe unit is calculated and displayed
by the system. It is determined from the sum of step times through the course of the recipe,
which in total equals the greatest time. The time is entered in steps as a value based on
experience. The calculation may include inaccuracies for recipe operations in which loops are
used. The output format is day:hours:minutes:seconds.
You can enter your own run time if you have previously selected the "Overwrite runtime" check
box.
Context help references
14.1 Dialogs