The two recipe elements (ROP_3 and RPH_3) that have not yet run and been deleted are
neither displayed in the control recipe window of BatchCC nor in the report or in XML archive
format.
9.8.8.8 How do I perform an online structure change?
Introduction
The following example shows you how to perform an online structure change and provides
you with background information on the system behavior.
Requirements
SIMATIC Logon is installed.
You have the individual permission "Begin structure change" in permission management.
The value of the "Allow online structure changes" project setting under Options > Settings
> Project setting > Batches is activated.
The master recipe or formula used for a batch has been released for testing.
No recipe unit procedure of the master recipe used may be executed on the AS.
BATCH Control Center
9.8 Batch control
SIMATIC BATCH V8.2
464 Operating Manual, 02/2016, A5E35958174-AA