The attribute can be dynamized with the OrderAndOrderCatEnabled name.
11.5.4.21 BatchSizeEnabled
Boolean variable.
With this attribute, you specify whether or not an operator is permitted to edit the text box for
the number of batches.
Default: Yes.
The attribute can be dynamized with the BatchSizeEnabled name.
11.5.4.22 BatchSize
Floating-point number.
With this attribute, you specify a value for the quantity in the control.
Default: 0, no quantity set.
The attribute can be dynamized with the BatchSize name.
11.5.4.23 BatchCountEnabled
Boolean variable.
With this attribute, you specify whether or not the number of completed batches is displayed
in the control.
Default: Yes.
The attribute can be dynamized with the BatchCountEnabled name.
11.5.4.24 BatchCount
Long integer.
With this attribute, you specify the required number of batches to be created.
Default: 1.
The attribute can be dynamized with the BatchCount name.
11.5.4.25 StartTimeVisible
Boolean variable.
This attribute specifies whether or not the start time of batches is displayed in the control.
Default: Yes.
The attribute can be dynamized with the StartTimeVisible name.
BATCH OS controls
11.5 Control properties references
SIMATIC BATCH V8.2
Operating Manual, 02/2016, A5E35958174-AA 661