● The following applies to direct nesting and stringing together of AND/OR logic operations
(parallel branches):
– Parallel branches must not be directly nested inside of one another.
– A parallel branch must not be followed directly by another parallel branch.
● Unit selection through conditions is to be used.
● The following recipe elements are not imported:
– Transitions
– Alternative branches
– Loops
– Jumps
– Monitoring
– Synchronization
– Library references
– Command steps
– Operator instructions
– Monitoring
● Properties of parameters, such as setpoint ID, visible externally, or modifiable, are not
imported.
● Transfer parameters, process tags and electronic signatures, as well as adaptation of
Runtime (linear or squared) for recipe operations are not imported.
● Formulas are not imported.
● Qualities of the main product are not imported.
Result
You use imported batches via COM API in the BATCH Control Center or in the BATCH OS
controls.
Additional information