3. Click on the "Yes" button. in the "User Account Control" dialog box.
4. Select the "NTLM (recommended)" option.
5. Enter the user name in the "Login" input box.
For the local user
" \User name"
Note
Even if "dots" are shown in the input box for the password, you need to enter a valid
password.
For the user of a domain
"Domain\User name"
6. Enter the password in the input box.
7. Click on the "OK" button.
8. Select the command BATCH Project > Start"
Result
The SIMATIC BATCH server system uses the NTLM mode.
Note
If the password elapses, the user is disabled or deleted, the SIMATIC BATCH server system
does not operate.
"Compatible" mode
If the "NTLM" mode does not work correctly, change the mode to "Compatible".
In this mode, the SIMATIC BATCH server system operates as in the past.
Additional information
You will find information on security aspects the section Security aspects (Page 75).
(1) You will find information on the right "Login as service" in the documentation of Windows.
Product introduction and installation
3.8 Configuring the security settings on the SIMATIC BATCH server
SIMATIC BATCH V8.2
78 Operating Manual, 02/2016, A5E35958174-AA