PD41
*DIA3
Input signal
automatic on
selection 3
Select input devices to turn on them automatically.
_ _ _ x (BIN): MD0 (operation mode selection 1)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
_ _ x _ (BIN): MD1 (operation mode selection 2)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
_ x _ _ (BIN): For manufacturer setting
x _ _ _ (BIN): For manufacturer setting
_ _ _ x (BIN): For manufacturer setting
_ _ x _ (BIN): For manufacturer setting
_ x _ _ (BIN): OVR (Analog override selection)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
x _ _ _ (BIN): For manufacturer setting
_ _ _ x (BIN): For manufacturer setting
_ _ x _ (BIN): For manufacturer setting
_ x _ _ (BIN): For manufacturer setting
x _ _ _ (BIN): For manufacturer setting
_ _ _ x (BIN): For manufacturer setting
_ _ x _ (BIN): For manufacturer setting
_ x _ _ (BIN): For manufacturer setting
x _ _ _ (BIN): For manufacturer setting
Convert the setting value into hexadecimal as follows.
PD42
*DIA4
Input signal
automatic on
selection 4
Select input devices to turn on them automatically.
_ _ _ x (BIN): For manufacturer setting
_ _ x _ (BIN): RT (Second acceleration/deceleration selection)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
_ x _ _ (BIN): RTCDP (Second acceleration/deceleration gain selection)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
x _ _ _ (BIN): For manufacturer setting
_ _ _ x (BIN): For manufacturer setting
_ _ x _ (BIN): For manufacturer setting
_ x _ _ (BIN): For manufacturer setting
x _ _ _ (BIN): For manufacturer setting
0
Initial value
BIN HEX
Input device
0
0
0 0
0
0
MD0 (Operation mode selection 1)
MD1 (Operation mode selection 2)
0
Initial value
BIN HEX
Input device
0
0
0OVR (Analog override selection)
BIN 0: Use for an external input signal.
BIN 1: Automatic on
0