Series 2600B System SourceMeter® instrument Reference Manual Section 14: Model 2400 emulation
2600BS-901-01 Rev. F/August 2021 14-13
Subsystem
Command
Supported
:SYSTem
:SYSTem:PRESet
Yes
:SYSTem
:SYSTem:RCMode SINGle|MULTiple
No
:SYSTem
:SYSTem:RCMode?
No
:SYSTem
:SYSTem:RSENse <Bool>
Yes
:SYSTem
:SYSTem:RSENse?
Yes
:SYSTem
:SYSTem:RWLock <Bool>
Yes
:SYSTem
:SYSTem:RWLock?
Yes
:SYSTem
:SYSTem:TIME?
Yes
:SYSTem
:SYSTem:TIME:RESet
Yes
:SYSTem
:SYSTem:TIME:RESet:AUTO <Bool>
Yes
:SYSTem
:SYSTem:TIME:RESet:AUTO?
Yes
:SYSTem
:SYSTem:VERSion?
Yes
:TRACe
:TRACe:CLEar
Yes
:TRACe
:TRACe:DATA?
Yes
:TRACe
:TRACe:FEED SENSe[1]|CALCulate[1]|CALCulate2
Yes
:TRACe
:TRACe:FEED?
Yes
:TRACe
:TRACe:FEED:CONTrol NEXT|NEVer
Yes
:TRACe
:TRACe:FEED:CONTrol?
Yes
:TRACe
:TRACe:FREE?
Yes
:TRACe
:TRACe:POINts <NRf>|DEFault|MINimum|MAXimum
Yes
:TRACe
:TRACe:POINts? [DEFault|MINimum|MAXimum]
Yes
:TRACe
:TRACe:POINts:ACTual?
Yes
:TRACe
:TRACe:TSTamp:FORMat ABSolute|DELTa
Yes
:TRACe
:TRACe:TSTamp:FORMat?
Yes
:TRIGger
:ABORt
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]]:COUNt <NRf>|DEFault|MINimum|MAXimum
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]]:COUNt?
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]]:SOURce
IMMediate|TLINk|TIMer|MANual|BUS|NSTest|PSTest|BSTest
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]]:SOURce?
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]][:TCONfigure][:ASYNchronous]:ILINe 1|2|3|4
Partially
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]][:TCONfigure][:ASYNchronous]:ILINe?
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]][:TCONfigure][:ASYNchronous]:OLINe 1|2|3|4
Partially
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]][:TCONfigure][:ASYNchronous]:OLINe?
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]][:TCONfigure][:ASYNchronous]:OUTPut
TENTer|TEXit|NONE
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]][:TCONfigure][:ASYNchronous]:OUTPut?
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]][:TCONfigure]:DIRection SOURce|ACCeptor
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]][:TCONfigure]:DIRection?
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]]:TIMer <NRf>
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]]:TIMer?
Yes
:TRIGger
:INITiate[:IMMediate]
Yes
:TRIGger
:READ?
Yes
:TRIGger
:TRIGger:CLEAr
Yes
:TRIGger
:TRIGger[:SEQuence[1]]:COUNt <NRf>|DEFault|MINimum|MAXimum
Yes
:TRIGger
:TRIGger[:SEQuence[1]]:COUNt? [DEFault|MINimum|MAXimum]
Yes
:TRIGger
:TRIGger[:SEQuence[1]]:DELay <NRf>|DEFault|MINimum|MAXimum
Yes
:TRIGger
:TRIGger[:SEQuence[1]]:DELay? [DEFault|MINimum|MAXimum]
Yes
:TRIGger
:TRIGger[:SEQuence[1]]:SOURce IMMediate|TLINk
Yes
:TRIGger
:TRIGger[:SEQuence[1]]:SOURce?
Yes
:TRIGger
:TRIGger[:SEQuence[1]][:TCONfigure][:ASYNchronous]:ILINe 1|2|3|4
Partially
:TRIGger
:TRIGger[:SEQuence[1]][:TCONfigure][:ASYNchronous]:ILINe?
Yes

Table of Contents