EasyManuals Logo
Home>Tektronix>Measuring Instruments>KEITHLEY 2600B Series

Tektronix KEITHLEY 2600B Series User Manual

Tektronix KEITHLEY 2600B Series
834 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #820 background imageLoading...
Page #820 background image
Series 2600B System SourceMeter® instrument Reference Manual Section 14: Model 2400 emulation
2600BS-901-01 Rev. F/August 2021 14-13
Subsystem
Command
Supported
:SYSTem
:SYSTem:PRESet
Yes
:SYSTem
:SYSTem:RCMode SINGle|MULTiple
No
:SYSTem
:SYSTem:RCMode?
No
:SYSTem
:SYSTem:RSENse <Bool>
Yes
:SYSTem
:SYSTem:RSENse?
Yes
:SYSTem
:SYSTem:RWLock <Bool>
Yes
:SYSTem
:SYSTem:RWLock?
Yes
:SYSTem
:SYSTem:TIME?
Yes
:SYSTem
:SYSTem:TIME:RESet
Yes
:SYSTem
:SYSTem:TIME:RESet:AUTO <Bool>
Yes
:SYSTem
:SYSTem:TIME:RESet:AUTO?
Yes
:SYSTem
:SYSTem:VERSion?
Yes
:TRACe
:TRACe:CLEar
Yes
:TRACe
:TRACe:DATA?
Yes
:TRACe
:TRACe:FEED SENSe[1]|CALCulate[1]|CALCulate2
Yes
:TRACe
:TRACe:FEED?
Yes
:TRACe
:TRACe:FEED:CONTrol NEXT|NEVer
Yes
:TRACe
:TRACe:FEED:CONTrol?
Yes
:TRACe
:TRACe:FREE?
Yes
:TRACe
:TRACe:POINts <NRf>|DEFault|MINimum|MAXimum
Yes
:TRACe
:TRACe:POINts? [DEFault|MINimum|MAXimum]
Yes
:TRACe
:TRACe:POINts:ACTual?
Yes
:TRACe
:TRACe:TSTamp:FORMat ABSolute|DELTa
Yes
:TRACe
:TRACe:TSTamp:FORMat?
Yes
:TRIGger
:ABORt
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]]:COUNt <NRf>|DEFault|MINimum|MAXimum
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]]:COUNt?
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]]:SOURce
IMMediate|TLINk|TIMer|MANual|BUS|NSTest|PSTest|BSTest
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]]:SOURce?
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]][:TCONfigure][:ASYNchronous]:ILINe 1|2|3|4
Partially
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]][:TCONfigure][:ASYNchronous]:ILINe?
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]][:TCONfigure][:ASYNchronous]:OLINe 1|2|3|4
Partially
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]][:TCONfigure][:ASYNchronous]:OLINe?
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]][:TCONfigure][:ASYNchronous]:OUTPut
TENTer|TEXit|NONE
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]][:TCONfigure][:ASYNchronous]:OUTPut?
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]][:TCONfigure]:DIRection SOURce|ACCeptor
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]][:TCONfigure]:DIRection?
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]]:TIMer <NRf>
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]]:TIMer?
Yes
:TRIGger
:INITiate[:IMMediate]
Yes
:TRIGger
:READ?
Yes
:TRIGger
:TRIGger:CLEAr
Yes
:TRIGger
:TRIGger[:SEQuence[1]]:COUNt <NRf>|DEFault|MINimum|MAXimum
Yes
:TRIGger
:TRIGger[:SEQuence[1]]:COUNt? [DEFault|MINimum|MAXimum]
Yes
:TRIGger
:TRIGger[:SEQuence[1]]:DELay <NRf>|DEFault|MINimum|MAXimum
Yes
:TRIGger
:TRIGger[:SEQuence[1]]:DELay? [DEFault|MINimum|MAXimum]
Yes
:TRIGger
:TRIGger[:SEQuence[1]]:SOURce IMMediate|TLINk
Yes
:TRIGger
:TRIGger[:SEQuence[1]]:SOURce?
Yes
:TRIGger
:TRIGger[:SEQuence[1]][:TCONfigure][:ASYNchronous]:ILINe 1|2|3|4
Partially
:TRIGger
:TRIGger[:SEQuence[1]][:TCONfigure][:ASYNchronous]:ILINe?
Yes

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix KEITHLEY 2600B Series and is the answer not in the manual?

Tektronix KEITHLEY 2600B Series Specifications

General IconGeneral
BrandTektronix
ModelKEITHLEY 2600B Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals