Layer 2 Switching Commands 409
Example
The following example shows the qualifications status of the optics on the
switch.
console#show interfaces transceiver
Port Dell Qualified
------------- ----------------
Te1/0/9 Yes
Te1/0/11 Yes
Te1/0/13 N/A
Te1/0/15 No
Te1/0/17 No
The following example shows static parameters of the optics along with the
qualifications status.
console#show interfaces transceiver properties
Yes: Dell Qualified No: Not Qualified
N/A : Not Applicable
Port Type Media Serial Number Dell Qualified
------------ ------- --------------- -------------------- --------------
Te1/0/9 SFP+ 10GBASE-LRM ANF0L5J Yes
Te1/0/11 SFP+ 10GBASE-LRM ANF0L5R Yes
Te1/0/13 SFP 1GBASE-SX PCC1PT5 N/A
Te1/0/15 SFP+ 10GBASE-SR AD1125A002R No
Te1/0/17 SFP+ 10GBASE-SR AD0815E00PC No
show statistics
Use the show statistics command to display detailed statistics for a specific
port or for the internal CPU interface.
Syntax
show statistics {gigabitethernet unit/slot/port |switchport |
port-channel
port-channel-number
| tengigabitethernet unit/slot/port |
fortygigabitethernet unit/slot/port}
unit/slot/port—
A valid physical interface identifier. See
Interface Naming
Conventions
for interface representation.
port-channel-number—
A port channel identifier.
switchport—Displays statistics for the internal switch CPU interface.

Table of Contents