When the system is powered on after a CPU has been replaced or
upgraded, the Global Error indicator will start flashing with the message
CPU has been changed.
This only indicates that the CPU configuration has been altered. There
is no technical problem.
Proceed as follows:
Restart your server.
As soon as the startup screen appears, press the [F2] function key to
enter the BIOS.
If a password is assigned, enter the password and press [Enter].
Select the Exit menu.
Select Commit settings and Exit.
Verify that the Global Error indicator stops flashing.
"Resuming BitLocker functionality" on page
105
.
Processor (CPU)
RX2540 M6 Upgrade and Maintenance Manual 365

Table of Contents

Other manuals for Fujitsu PRIMERGY RX2540 M6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX2540 M6 and is the answer not in the manual?

Fujitsu PRIMERGY RX2540 M6 Specifications

General IconGeneral
Memory Slots32 DIMM slots
Form Factor2U rack server
ProcessorIntel Xeon Scalable Processors (3rd generation)
StorageUp to 24 x 2.5" or 12 x 3.5" drives
RAID SupportRAID 0, 1, 5, 6, 10
Network4 x 1GbE ports (onboard), optional 10/25GbE
Power Supply800 W, 1200 W, 1600 W
Expansion SlotsUp to 8x PCIe Gen4 slots
Operating System SupportWindows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware
ManagementiRMC S5

Related product manuals