EasyManua.ls Logo

Lexmark MS911 - Page 176

Lexmark MS911
719 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Action Yes No
Step 14
a Remove the rear cover.
b Bypass the front door switch.
c Test the motor (SHPF elevator).
Enter the Diagnostics menu, and then navigate to:
MOTOR TESTS > Staple and Hole Punch Finisher Motor Tests >
Elevator
d Check if the elevator is moving properly.
Is it moving properly?
Go to step 16. Go to step 15.
Step 15
a Reseat the cable on the motor.
b Make sure that the motor is properly installed.
c Check the motor and cable for damage, and replace if necessary.
Does the problem remain?
Go to step 16. The problem is solved.
Step 16
a Make sure that the sensor (SHPF elevator position) is properly
installed.
b Make sure that the sensor is free of debris or dust.
c Reseat the cable on the sensor. Check the cable for damage, and
replace if necessary.
d Check the sensor for damage, and replace of necessary. See “Sensor
(SHPF elevator position) removal” on page 361.
Does the problem remain?
Go to step 17. Go to step 18.
Step 17
Replace the sensor. See
“Sensor (SHPF elevator position) removal” on
page 361.
Does the problem remain?
Go to step 18. The problem is solved.
Step 18
a Make sure that the elevator drive gears, elevator motor encoder, and
encoder belt are properly installed.
b Check the parts for damage, and replace if necessary.
Does the problem remain?
Go to step 19. The problem is solved.
Step 19
a Make sure that the elevator belts and gears are properly installed.
b Check the belts and gears for wear or damage, and replace if
necessary. See
“SHPF elevator belts removals” on page 377.
Does the problem remain?
Go to step 20. The problem is solved.
4021, 7421
Diagnostic information
176