365-575-102 CircuitOrder:
Issue 8.0, July 2002 Page 1 of 4
NTP-013
Remove OC-12 Circuit Pack(s) From the Shelf
DO ITEMS BELOW IN ORDER LISTED . . . . . . . FOR DETAILS, GO TO
1. Required Test Equipment:
Craft Interface Terminal (CIT)
Wrist Strap
!
WARNING:
Unterminated optical connectors may emit invisible laser radiation. Eye
damage may occur if the beam is viewed directly or with improper
optical instruments. Avoid direct exposure to beam.
!
CAUTION:
Use a static ground wrist strap whenever handling circuit packs or
working on an FT-2000 terminal to prevent electrostatic discharge
damage to sensitive components. See "Electrostatic Discharge (ESD)
Considerations" in Trouble Clearing: TAD-100.
Obtain the circuit order instructions to
remove an OC-12 circuit pack(s) and note
the assigned address. The address
requires a slot assignment.
—
2. If required, connect and condition the craft
interface terminal (CIT).
DLP-501
3. At the CIT, select the
CONFIGURATION-Retrieve-CKT-STS3
command (or the
CONFIGURATION-Retrieve-CKT-STS1
command) for the slot address indicated in Step
1 and obtain an STS-3 (or STS-1) Circuit Map
Report.
—