Craft Interface Terminal Usage
Issue 8.0 July 2002
11-119
Example 38 - PERFORMANCE-Retrieve-PM Threshold-Section 11
(Releases 7 and Later)
The report shows the current performance-monitoring threshold crossing alert
(TCA) values for the STS-48 section. This report is not available at the repeater
site.
Delta-1 93-01-15 13:15:15 EST
M Retrieve-PM Threshold-Section:All: COMPLD
/* STS-48 Section Performance Monitoring Threshold Value Report
==========================================================================
--------- STS-48 Section (B1) --------
Address Bin BER CV-S ES-S SES-S SEFS-S
==========================================================================
line-1e QH -9 1000 25 10 5
Day -9 1000 3 250 50
line-1w QH -9 1000 25 10 5
Day -9 1000 3 250 50
*/
;
/* STS-48 TCA Autonomous Reporting Status Report
==========================================================================
TCA --------- STS-48 Section (B1) --------
TCA Report TCA Report TCA Report TCA Report TCA Report
Address Bin BER CV-S ES-S SES-S SEFS-S
==========================================================================
line-1e QH Enable Disable Enable Disable Disable
Day Enable Disable Enable Disable Disable
line-1w QH Enable Disable Enable Disable Disable
Day Enable Disable Enable Disable Disable
*/