Administration and Provisioning
Issue 8.0 July 2002
8-99
FT-2000 OC-48 Add/Drop-Rings Terminal 8
Table 8-5 shows the provisionable parameters of the FT-2000 OC-48
Add/Drop-Rings Terminal. This includes the parameters that can be provisioned
using the CIT, plus the parameters that are automatically provisioned or have
fixed values (cannot be changed). The original value for each provisionable
parameter in Table 8-5 is shown in brackets [ ]. Table 8-5 also shows the
applicable CIT-PC and TL1 commands.
Table 8-6 shows the provisionable threshold crossing alert (TCA) parameters of
Add-Drop-Rings Terminal. This includes the threshold range and original values
for the quarter-hour and day bins of each performance-monitoring parameter. The
original value for each provisionable parameter in Table 8-6 is shown in
brackets [ ].
Table 8-5. Provisionable Parameters (FT-2000 OC-48 Add/Drop-Rings Terminal)
Parameter Options [Original Value] Method
CIT-PC Input
[TL1 Command]
CIT-PC Report
[TL1 Report]
System Address
SECURITY-Set-Ne
twork-Element
[ENT-SYS]
SECURITY-Retriev
e-
Network-Element
[RTRV-SYS]
- Target Identifier (TID) [LT-FT-2000]≤
20 characters
CIT
- Node Identifier (NID)§§§ 0-15 [0]
- Directory Service NE Yes, [No]
-X.25PacketSize¶¶¶ 128, [256]
- Alarm Group¶¶¶ 0-[255]
- Alarm Gateway Network Element
(AGNE)¶¶¶
Yes, [No]
- TL1 Gateway Network Element
(GNE)‡‡‡
Yes, [No]
- Site Address
site-line-site number
Automatic None
- Network Services Access Point
(Releases 3 and 4 only)
≤ 40 Characters
[No Original Value]
Automatic None CONFIGURATION-Re
trieve-Map-Ring
[RTRV-MAP]
Synchronization
- Provisioned Mode [Externally Timed], Through
Timed, Free Running, Line
Timed, (Phase Locked prior to
Rel. 5)
- Pri. DS1 In Format [SF], ESF CONFIGURATION- CONFIGURATION-
- Pri. DS1 In/Out Format* [SF], ESF CIT Set- Retrieve-
- Sec. DS1 In Format [SF], ESF Synchronization Synchronization
- Sec. DS1 In/Out Format* [SF], ESF
- Pri. DS1 In Line Code [AMI], B8ZS
- Sec. DS1 In Line Code [AMI], B8ZS
- DS1 Out 1 Equalization [20], 40, 60, 80, 100 Percent
- DS1 Out 2 Equalization [20], 40, 60, 80, 100 Percent