Craft Interface Terminal Usage
11-132 Issue 8.0 July 2002
Example 43 - SECURITY-Retrieve-Security-Network Element 11
Releases 4.1 and Later (Use the SECURITY category.)
The above report shows global security information for the local FT-2000 network
element.
Releases 2, 3, and 4.0 (Use the SECURITY category.)
The above report shows global security information for the local FT-2000 network
element.
Logins Allowed - Shows if nonprivileged users are allowed to log in or not.
Privileged users are always allowed to log in.
Password Aging - For Release 4.1 and later. Shows the lifetime interval in
days before the user must select a new password. A
zero interval will disable this parameter.
Login Aging - For Release 5.0 and later. Shows the lifetime interval in
days before the user must select a new login. A zero
interval will disable this parameter.
Logins Allowed - Shows if nonprivileged users are allowed to log in or
not. Privileged users are always allowed to log in.
Delta-1 93-01-19 23:15:15 EST
M Retrieve-Security-Network Element: COMPLD
/* Access Security Global Configuration Report
=============================================================
Parameter Value
=============================================================
Logins Allowed yes
Password Aging 60 days
Login Aging 60 days
*/
;
Delta-1 93-01-19 23:15:15 EST
M Retrieve-Security-Network Element: COMPLD
/* Access Security Global Configuration Report
=============================================================
Parameter Value
=============================================================
Logins Allowed yes
*/
;