365-575-102 Acceptance: NTP-006
Issue 8.0, July 2002 Page 1 of 6
Accept FT-2000 OC-48 Add/Drop-Rings Terminal for
2-Fiber Ring
DO ITEMS BELOW IN ORDER LISTED . . . . . . . FOR DETAILS, GO TO
1. Overview: This acceptance procedure tests an out-of-service FT-2000
OC-48 Add/Drop-Rings Terminal for a 2-fiber ring in a stand-alone state.
Each FT-2000 terminal (node) in the FT-2000 ring network should be
tested individually.
Required Test Equipment:
Craft Interface Terminal (CIT)
Wrist Strap
Optical Loopback Jumpers with 20-dB buildout
!
WARNING:
Unterminated optical connectors may emit invisible laser radiation. Eye
damage may occur if beam is viewed directly or with improper optical
instruments. Avoid direct exposure to beam.
!
CAUTION:
Use a static ground wrist strap whenever handling circuit packs or working
on an FT-2000 terminal to prevent electrostatic discharge damage to
sensitive components. See "Electrostatic Discharge (ESD) Considerations"
in Trouble Clearing: TAD-100.
NOTE:
This procedure is only used if the FT-2000 add/drop-rings terminal was
installed by someone else. If the installation has not been completed
(including circuit pack installation), notify the installation personnel or refer
to 365-575-115 to complete the installation. If you completed the
installation following the procedures in 365-575-115, do not perform
this procedure.