Craft Interface Terminal Usage
Issue 8.0 July 2002
11-97
Example 28 - PERFORMANCE-Retrieve-PM Mode-T3 11
The above report shows the algorithm used for determining and accumulating
DS3 path performance monitoring data, either P-bit processing or F-bit and M-bit,
adjusted processing.
Port
Address
- Shows the AID of low-speed port.
DS3 Mode - Shows the provisioned algorithm used to determine and
accumulate the DS3 path performance data (P-bit or F&M-bit).
Delta-1 94-06-15 23:15:15 EST
M Retrieve-PM Mode-T3:All: COMPLD
/* DS-3 Performance Monitoring Mode Report
=====================================================================
Port DS3
Address Mode
=====================================================================
ls-1a-1 P-bit
ls-1a-2 P-bit
ls-1a-3 F&M-bit
.
.
.
ls-8b-3 P-bit
*/
;