Administration and Provisioning
8-98 Issue 8.0 July 2002
Provisioning 8
Provisionable Parameters and Original Values 8
General 8
Installation provisioning is minimized with provisionable parameters and original
values. Each CIT provisionable parameter is assigned an original value. The
provisionable parameters and original values are copied from floppy disks in the
CIT to the SYSMEM circuit pack.
The SYSMEM circuit pack contains one copy of the provisionable parameters with
their original values and another copy of the provisionable parameters with their
current values. The SYSCTL and LNCTL circuit packs, plus the board controllers
on the other circuit packs contain one copy of the provisionable parameters with
their current values.
The original values cannot be changed. The current values can be changed
through local provisioning.
NOTE:
The FT-2000 OC-48 Lightwave System has no switch-settable parameters.