DLP-506: Detailed Level Procedure 365-575-102
Page4of6 Issue8.0,July2002
NOTE:
A flashing FAULT LED on the RCVR circuit pack indicates a loss of signal from
the other end.
22. Verify all connectors are secure for the OC-48 lines and the fibers are dressed
into their slots.
23. Replace the front shelf cover to the high-speed shelf.
Reference: DLP-511
24. Return to Step 1 for any remaining network elements in the FT-2000 network.
FT-2000 Repeater Bay/Shelf (Figure 2)
25. Perform Steps 2 through 24 for each repeater in the FT-2000 network, but sub-
stitute the REGENR circuit pack in place of the TRMTR and RCVR circuit
packs. The REGENR OUT connector represents the TRMTR and the IN con-
nector represents the RCVR. Also, the OC-48 optical lines use 1 for service
and P for protection along with east and west for direction. For example, 1WE
means the service line has optical transmission in a west to east direction.
26. STOP! YOU HAVE COMPLETED THIS PROCEDURE.